VIGAZ CANAL100/120 II analyzer

What it is for and who uses it

The CANAL100/120 II is an analyzer for measuring modified atmospheres in food packaging: the CANAL100 version measures O₂ and the CANAL120 version measures O₂ and CO₂. According to the VIGAZ data sheet, it is a benchtop instrument for production or laboratory environments. It is easy to use: a measurement is started at the press of a button and stops when the sensors have finished reacting; the values are then frozen, so each measurement is almost automatic. At start-up it draws in air to calibrate itself automatically at 20.95 %.

Specifications

According to the VIGAZ technical data sheet:

CANAL100/120 II specifications
ParameterValue
FormatBenchtop
Measured gasesO₂ (CANAL100) · O₂ and CO₂ (CANAL120)
O₂ sensorElectrochemical · range 0-100 % · accuracy ±1 % relative · resolution 0.01 % · response (T90) 10 s · service life 4 years in air
CO₂ sensor (CANAL120)Infrared · range 0-100 % · accuracy ±2% · resolution 0.1 % · response (T90) 9 s · service life unlimited
Operating temperature0 to +40 °C
ProtectionIP54
Display4-line digital
Power supply100-230 V - 50/60 Hz
Dimensions29 x 19 x 7 cm
Weight1.5 kg
FunctionsAutomatic O₂ calibration in air at start-up (20.95 %) · calibration menu protected by a 4-digit security code · values locked after each measurement · timed pump: programmable delay from 0 to 20 s; automatic mode: first 5 s suction and, if the measurement has not stabilised, a second 5 s suction · low sample withdrawal volume · long-life O₂ sensor
CalibrationWith standard gases: O₂ zero / O₂ calibration
Supplied withSpiral sampling kit · foams, filters and needles · calibration certificate and instructions for use

Scroll horizontally to see the whole table.

Data according to the manufacturer's (VIGAZ) technical data sheet.

How it is used, according to the data sheet: insert the needle through a septum and press "P"; the pump draws the sample for the programmed time, an hourglass shows the progress of the measurement and, once the reading has stabilised, it is locked on the display. There is no need to draw in air between one measurement and the next.

Position in the range

What sets it apart, according to the VIGAZ data sheets: a single data sheet covers the CANAL100 (O₂) and CANAL120 (O₂ and CO₂) versions. It is powered at 100-230 V - 50/60 Hz, measures 29 x 19 x 7 cm, weighs 1.5 kg, has IP54 protection and an O₂ resolution of 0.01 %. By contrast, the CANAL111 II and CANAL121 III run on a rechargeable 9 V NiMH battery with an O₂ resolution of 0.1 %, and the BOX100 II and BOX120 II models have IP65 protection.

Documentation and contact

Request a quotation or the CANAL100/120 II technical data sheet.

Enquire about the CANAL100/120 II

Request a quotation or the CANAL100/120 II data sheet.

VIGAZ use and documentation

According to VIGAZ, CANAL100/120 II is a benchtop instrument for production or laboratory environments. Explore the analyzer range and the MAP oxygen analyzer guide.